For visitors and participants a large cloak room is available. For relaxation of the actors there are relaxation areas. A sufficient number of changing rooms, showers and washing facilities is also available. All changing rooms can be locked and are equipped with heating. Full-length mirrors and refrigerators can be pre-ordered. For loading and unloading access can be granted via the ramp of the stage foyer (access via Selikumer Str.). Parking for trailer trucks and nightliners and broadcasting spaces for TV broadcasts are available as well. The town hall has an entrance foyer (823 m²), a stage foyer (206 m²) and a garden foyer (422 m²) as well as mobile bar facilities, dance floors, dividing walls, pedestals and lighting and sound systems.
Cloak Room
- Each jacket, etc. 1 EUR
- Large items such as suitcases, etc. 2 EUR
- Items can be checked in and out during opening hours
- Valuables such as jewelry, money, wallet, etc. cannot be stored
- We do not assume any liability
Technical Data and Specifications at FANTASYDAYS®
Stage Specifications
The hall of the town hall has a stage with the following dimensions:
Portal
- portal width max. 19.10 m
- portal width min. 11.10 m
- portal height 4.68 m
Height of Stage
- Bowden cable rest position 6.50 m
- Bowden lamp cables rest position 5.80 m
Stage Depth
- to opera foil 9.60 m
- to curtain 8.30 m
Forestage
With the help of our hydraulic stage it is possible to extend the main stage. If the stage is not used, the forestage can be utilized to emphasize the committee table (congresses, seminars). The stage is adjustable in height and can be used for special presentations of projects (e.g. cars). It can be an impressive effect to lift these items from the ground to hall or stage level.
- Width: 12.00 m without extension
- Width: 20.00 m with extension
- Orchestra pit
Fly System
There are 11 linesets with a maximum height of 6.50 m and 2 linesets with a maximum height of 5.80 m. The maximum load bearing capacity is 200 kp, the maximum point load is 75 kp.
Lighting
The modern lighting equipment in the town hall, which is centrally controlled from the control room, has the following electrical supply connections:
- 4 x 63 A CEE (stage)
- 1 x 125 A fixed connection (stage)
- 4 x 63 A CEE (hall)
- 1 x 16 A CEE (hall)
- 4 x 63 A CEE (high performance room)
- 1 x 63 A CEE (entrance foyer)
Hall Lighting:
- normal light
- approx. 180 Lux, fully dimmable
- can be controlled from the hall, otherwise from the control room
- dance floor lighting
- 20 x 12 m, 500 Lux (intern. dance floor dimensions)
- spotlights washable (20 MST 1023 Fresnel lenses)
Foyer Zones:
- STAFFSYSTEM (with spots)
- individual wall lighting (for exhibitions)
Stage Lighting (standard):
- 1 control desk
- manual with 76 electric circuits in 3 lines
- with main cross-fader and free line pre-selection
- DMX connection (Mittmann Elektronik)
- 1 light control console
- Mittmann
- The standard stage lighting will be supplemented by us.
Mobile Lighting Specifications:
- 52 Fresnel lens spotlights
- 1 kW, Mittmann, Type MST 1023
- 14 profile spotlights
- 2 kW, Rank Strand, Type Gardenza 121222
- 20 profile spotlights
- 650 Watt, Coema Accento 20/35
- 6 lens spotlights
- 1 kW, Mittmann, Type MPL 1034
- 49 flood lights
- 0.75 kW, Mitmann, Type MFL 0720 (lifting podium + stage)
- 10 flood lights
- Teatro di Invio, A 100 asymmetric
- 2 chaser lights
- Control room, 2 kW, Mittmann (only via control desk)
- MVK 2070
- 1 chaser light
- Control room, Testa MD 1200 MSR (controlled freely)
|